EasyManua.ls Logo

Fronius TransSteel 5000 Syn - General; Documented Welding Data

Fronius TransSteel 5000 Syn
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General
General If the Easy Documentation option is available on the power source, the most im-
portant welding data for each weld can be documented and saved as a CSV file
on a USB flash drive.
A Fronius signature is stored with the welding data which can be used to check
and guarantee the authenticity of the data.
Easy Documentation is activated / deactivated by plugging / unplugging the sup-
plied Fronius USB flash drive with FAT32 formatting into the back of the power
source.
IMPORTANT! To document the welding data, the date and time must be set cor-
rectly.
Documented
welding data
The following data is also documented:
Device type
File name
Item number
Serial number
Firmware version of power source
Firmware of PC board DOCMAG (Easy Documentation)
Docu version
https://www.easydocu.weldcube.com (a PFDF report of selected welding data
can be created under this link)
Nr. Counter
Start by plugging in the USB flash drive;
When switching the power source off and on, the counter contin-
ues at the last weld seam number.
A new CSV file is created after 1000 welds.
Date Date yyyy-mm-dd
Time Time hh:mm:ss
at start of current flow
Duration Duration in [s]
from start of current flow to end of current (current flow signal)
I Welding current * in [A]
U Welding voltage * in [V]
vd Wire speed * in [m/min]
wfs Wire speed * in [ipm]
IP Power * from instantaneous values in [W]
IE Energy from instantaneous values in [kJ]
across the entire weld
I-Mot Motor current * in [A]
Synid Characteristic number
per weld
Job EasyJob number
per weld seam