Setup menu (2nd) are also not deleted. Exception: Ignition time-out func-
tion parameter (ito).
2nd Second level of the Setup menu (see "Setup menu - level 2")
Setup paramet-
ers for
MIG/MAG
standard syner-
gic welding
"Min." and "max." are used for setting ranges that differ according to power
source, welding program, etc.
GPr Gas pre-flow time
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.1
GPo Gas post-flow time
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.5
SL Slope (special 4-step mode only)
Unit: s
Setting range: 0 - 9.9
Factory setting: 0.1
I-S I (current) - Starting - Starting current (special 4-step mode only)
Unit: % (of welding current)
Setting range: 0 - 200
Factory setting: 100
I-E I (current) - End: Final current (special 4-step mode only)
Unit: % (of welding current)
Setting range: 0 - 200
Factory setting: 50
t-S t (time) - Starting - Starting current duration (special 4-step mode only)
Unit: s
Setting range: OFF, 0.1 - 9.9
Factory setting: OFF
t-E t (time) - End: Final current duration (special 4-step mode only)
Unit: s
Setting range: OFF, 0.1 - 9.9
Factory setting: OFF
Fdi Feeder inching - feeder inching speed
Unit: m/min (ipm)
Setting range: 1 - max. (39.37 - max.)
Factory setting: 10 (393.7)
bbc Burn-back time correction - burn-back effect
Wire burn-back effect through wire withdrawal at end of welding, regard-
less of the selected characteristic
Unit: s
Setting range: Aut, 0 - 0.3
Factory setting: Aut