112
1. Fit copper clips (5) and (6)
2. Feed „outer blue primary lead“ through cut-outs (18) on PC board and clamp in
place with terminal screw (19)
3. Feed „outer orange primary lead“ through cut-outs (20) on PC board and clamp in
place with terminal screw (21)
4. Clamp „inner blue primary lead“ using terminal screw (22)
5. Clamp „inner orange primary lead“ using terminal screw (23)
6. Fit side panel
Fig. 9 Connecting transformer 2
Fitting transfor-
mer
(continued)
(5)
(6) (21)
(19)
(18)
(20)
(22)
(23)