www.fubag.ru
Omperator's anual
--4
1. To select charging mode or re-set during charging.
2. .
3.Battery repairing.
4. Battery is during charging.
5. Battery is full.
6. Mode 14.4V/1.0A. This mode is normally used for all types of 12V batteries <20Ah.
7. Mode 14.4V/4.0A. This mode is normally used for all types of 12V batteries <80Ah.
Mode 14.7V/4.0A This setting is recommended for batteries at temperatures below 5 C. It is also
recommended for many AGM batteries. This setting is not recommended for maintenance charging
when the temperature at times exceeds +5 C. In this case, the 14.4V/4Amode is recommended
. Mode 7.5V/4.0A. This mode is normally used for all types of 6V batteries <80Ah.
10. Fault. ight on in case of short circuit, reverse polarity, bad battery.
1. When you are sure the battery leads are correctly connected, plug the power cord to the power
outlet to start charging. If the battery leads are wrongly connected, The fault lamp 10 will light.
2. Set the proper charging mode for the battery by pushing the Mode button 1 until the correct
setting is light.
3. The charging lamp 4 now light on indicating charging .
The maintenance lamp 5 will on when the battery is fully charged and now is in trickle charge. If the
voltage drops the charger sends current to the battery. The charger can be connected for months.
4.If battery voltage is less than 10Volt, charger will give impulse to arouse the battery, repair lamp 3
will light , charger will turn to normal charge mode when battery reach 12V.
5. If battery is slightly sulphated , charger will try to desulphate it. Then repair lamp 3 will light on.
Repairing may take 0.5-2hour. Charger will turn to to normal charge mode when battery is
recovered. If battery can't be recovered , fault lamp 10 will light and charge stops.
6. Charging can be stopped at any time by disconnecting the supply cord or by push mode button 1.
7. If fault lamp 10 is on during charging , the reason for this is due to:
An interruption during charging, due to a loose connection or because the battery has ceased to
work.
The battery has become severe sulphated or dead and needs to be replaced.
The battery has a high self-discharge rate and may need to be replaced.
WARNING: DO NOT attempt to charge a frozen battery.
DO NOT leave the charger to battery without main power connected.
Light ON
8. . °
°
9
L
-
-
-
5. Start to charge