CHAPTER 2 WIRING
Description of I/O Signals 2-79
2
Home position LS detection: Sequence output signal (Reference value 40)
The signal is output while the home position LS signal (input signal) remains turned on.
Function
The sequence output corresponding to home position LS detection is turned on while the home
position LS sequence input signal remains turned on.
Parameter setting
To assign home position LS detection to a sequence output terminal, specify the corresponding
value ("40") to the output terminal function setting parameter.
Forced stop detection: Sequence output signal (Reference value 41)
The signal is turned on while the forced stop signal (input signal) remains turned on (relay:open).
Function
Forced stop detection is turned on when the forced stop sequence input signal is turned on
(relay:open). For details, refer to "Forced stop."
Parameter setting
To assign forced stop detection to a sequence output terminal, specify the corresponding value
("41") to the output terminal function setting parameter.
Battery warning: Sequence output signal (Reference value 45)
The signal is output if the battery voltage is smaller than the rated value.
Function
If the battery voltage is smaller than the rated value in an established ABS system (absolute
system), a battery warning signal is turned on.
Parameter setting
To assign battery warning to a sequence output terminal, specify the corresponding value ("45") to
the output terminal function setting parameter.
Replace the battery immediately if this signal is turned on.