CHAPTER 6 KEYPAD
6-16
Monitor Mode
6
(8) Command position (displayed digits: signed 10 digits)
The position of the servomotor controlled by the servo
amplifier is displayed in the unit amount after correction
with an electronic gear. If the operation command is turned
off and the load (mechanical system) rotates the motor
after the target position is reached, the position is not
correct.
on08
SET
(1 sec. or over)
99
----
9999
----
-99
SHIFT
9999
----
Blinks three times.
SHIFT
Blinks three times.
9999
-999
9999
-999
ESC
ESC
ESC
With a negative data
The figure and "-" symbol are displayed alternately.
With a negative data
With a negative data
The figure and "-" symbol are displayed alternately.
U
L

Table of Contents