CHAPTER 6 KEYPAD
6-52
Test Operation Mode
6
*[Cause of NG1 indication]
The parameter PA1_13 (tuning mode) is set to "12" (manual).
The parameter PA2_74 (parameter write protection) is set to "1" (write protect).
Operation is disabled due to EMG detection or alarm detection.
During motor rotation.
[Cause of NG2 indication]
Operation is stopped due to ±OT detection, EMG detection, and S-ON signal OFF, etc.
[Cause of NG3 indication]
The motor is oscillating even when the auto tuning gain is set to 4 or lower.
Fn12
Esy
SET
(1 sec. or over)
ESC
SET
(1 sec. or over)
Select the desired operation by pressing the [
]
and [] keys.
nG
ESC
∧/∨
ESC
_ESY
SET
(1 sec. or over)
Ends prematurely by
pressing ESC.
Operation confirmed
8
E
SY
During easy tuning
_StP
Returns by
pressing ESC.
The lit arrow moves along a figure of
eight.
Operation stop
completion
_End
Easy tuning completion
*
ESY
・・・
SLr
Slow run Easy tuning

Table of Contents