EasyManua.ls Logo

Fuji Electric ALPHA5 Smart - Encoder Cable

Fuji Electric ALPHA5 Smart
636 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 10 PERIPHERAL EQUIPMENT
10-6 Cable Size
10
10.2.2 Encoder Cable
Use the specified shield cable for encoder wiring of the servomotor.
The optional cable for the servomotor is a UL-rated cable having bend resistance.
Use a regular twisted pair batch shield cable if the servomotor and cable do not move.
Cross linked polyethylene vinyl sheath cable for robot travel (flame-resistant) (Daiden
Co., Ltd.)
RMCV-SB AWG#25/2P + AWG#23/2C or AWG#23/3P
(For 10 m or smaller wiring length)
RMCV-SB AWG#25/2P + AWG#17/2C or its equivalent
(For wiring lengths < 10 m and 50 m)
The relationship between AWG and mm is shown below.
Gauge SI unit Inch unit
A.W.G In [mm
2
]
Diameter
[mm]
Cross
section
[mm
2
]
Diameter
[mil]
Cross
section [CM]
16 1.25 1.291 1.309 50.82 2583
17 - 1.150 1.037 45.26 2048
18 - 1.024 0.8226 40.30 1624
19 - 0.9116 0.6529 35.89 1288
20 - 0.8118 0.5174 31.96 1021
21 - 0.7299 0.4105 28.46 810.0
22 - 0.6438 0.3256 25.35 642.6
23 - 0.5733 0.2518 22.57 509.4
24 - 0.5106 0.2024 20.10 404.0
25 - 0.4547 0.1623 17.90 320.4

Table of Contents

Related product manuals