CHAPTER 10 PERIPHERAL EQUIPMENT
Optional Equipment 10-31
10
Power supply and motor power conncetor (Amplifier side)
Model: WSK-S06P-F
Applicable range: GYBGYCGYS model・・・・0.4 [kW]or less
External Dimension
Model and manufacturer
Power supply conncetor (Amplifier side)
Model: WSK-S03P-F
Applicable range: GYB model・・・・0.75 kW
GYG model・・・・0.5 to 2.0 kW
GYC model・・・・0.75 to 2.0 kW
GYS model・・・・0.75 to 3.0 kW
External Dimension
Model and manufacturer
Recommended RYH type (frame 3) /UL standard compatible power supply
connector (amplifier side)
Applicable range: GYH type・・・・3.0 kW 4.0 kW
GYG type・・・・1.3 kW 2.0 kW
GYC type・・・・2.0 kW
GYS type・・・・2.0 kW 3.0 kW
Model and manufacturer
Connector 03JFAT-SAXGFK-XL
Open tool J-FAT-OT-EXL
J.S.T. Mfg. Co., Ltd.
Connector 06JFAT-SAXYGG-F-KK
Open tool J-FAT-OT
J.S.T. Mfg. Co., Ltd.
Terminal layout
Connector 03JFAT-SAXGSA-L
Open tool J-FAT-OT
J.S.T. Mfg. Co., Ltd.
Terminal layout
Symbol Terminal Symbol Terminal
A1 L1 B1 U
A2 L2 B2 V
A3 L3 B3 W
Pin no. 1 2 3
Name L1 L2 L3