CHAPTER 12 POSITIONING DATA
12-2 Operation Modes
12
12.1 Operation Modes
12.1.1 Operation Method
Positioning operation based on positioning data and immediate value data can be conducted with this
servo amplifier.
(1) Positioning data operation
Set data items to positioning data inside the servo amplifier in advance and designate the
address (data number) of the desired operation data among AD0 to AD3 at the host controller,
etc.
Turn on the start positioning (START) to execute the positioning operation according to the
preset data.
Interface: Di / Do signal or RS-485 communications (Modbus-RTU)
Up to 15 points can be registered as positioning data.
Register data, using PC Loader or at the keypad.
Host controller
Address (AD0 to AD3)
Start positioning (START)
Positioning data NO.1
- Position data
- Speed data
- Timer data
- M code
- Status
- Acceleration time
- Deceleration time
Positioning data NO.2
- Position data
- Speed data
- Timer data
- M code
- Status
- Acceleration time
- Deceleration time
Positioning data NO.15
- Position data
- Speed data
- Timer data
- M code
- Status
- Acceleration time
- Deceleration time