EasyManua.ls Logo

Fuji Electric ALPHA5 Smart - Page 504

Fuji Electric ALPHA5 Smart
636 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 13 RS-485 COMMUNICATIONS
13-16
Modbus RTU Communications
13
4. Addresses
The addresses of various data are as follows:
Data addresses
[Table 13-1] Fixed data address list
Applicable
FC
Data type Data name
Address
(hex.)
03h 10h
Format
(with a sign)
Setting range
(default value)
Communication
CONT signal
0000
Refer to [5-1]
0-FFFFh (0: OFF all)
Communic-
ation
CONT/OUT
signals
Communication
OUT signal
0100
Refer to [5-1]
Feedback speed
1000
1h=1 r/min
(Yes)
Command speed
1001
1h=1 r/min
(Yes)
Command torque
1002
1h=1%
(Yes)
Peak current
1003
1h=1%
(Yes)
Motor current
1004
1h=1%
(Yes)
Effective torque
1005
1h=1%
(No)
Feedback position
1006
1h=1 unit
(Yes)
Command position
1007
1h=1 unit
(Yes)
Position deviation
1008
1h=1 (*1)
(Yes)
Command pulse
frequency
1009
1h=0.1 kHz
(No)
Feedback
cumulative pulses
100A
1h=1 pulse
(Yes)
Cumulative input
pulses
100B
1h=1 pulse
(Yes)
LS-Z pulse
100C
1h=1 pulse
(No)
Load inertia ratio
100D
1h=0.1 times
(No)
DC link voltage (max.)
100E
1h=1 V
(No)
DC link voltage (min.)
100F
1h=1 V
(No)
VREF input voltage
1010
1h=0.01 V
(Yes)
TREF input voltage
1011
1h=0.01 V
(Yes)
Monitor
OL thermal value
1012
1h=1%
(No)

Table of Contents

Related product manuals