CHAPTER 13 RS-485 COMMUNICATIONS
Modbus RTU Communications 13-17
13
Applicable
FC
Data type Data name
Address
(hex.)
03h 10h
Format
(with a sign)
Setting range
(default value)
Regenerative resistor
thermal value
1013
1h=1%
(No)
Power (W)
1014
1h=1%
(Yes)
Motor temperature
1015
1h=1°C
(No)
Overshoot unit
amount
1016
1h=1 (*1)
(Yes)
Settling time
1017
1h=0.1 ms
(No)
Resonance frequency
1
1018
1h=1 Hz
(No)
Monitor
Resonance frequency
2
1019
1h=1 Hz
(No)
Hardware CONT
signal
2000
Refer to [5-1]
Hardware OUT
signal
2001
Refer to [5-1]
Control mode
2100
Refer to [5-1]
Sequence mode
2101
Refer to [5-1]
Alarm at present
2200
Sequence
monitor
Alarm history 1-20
2201-2214
Refer to [5-2]
Anti resonance
frequency
3002 1h=0.1 Hz
(No)
0.0, 1.0-300.0
(0.0: The vibration
suppressing control
function is disabled.)
Various
commands
Workpiece inertia
ratio
3003 1h=1%
(No)
0-80 (0)
PA1_1-99
4000-4062
PA2_1-99
4100-4162
Parameter
PA3_1-99
4200-4262
The parameter is
followed.
The parameter is
followed.
Immediate value
status
5100 Refer to [5-3]
Immediate value
position
5101 1h=1 unit
(Yes)
0-±2000000000 (0)
Immediate value
speed
5102 1h=0.01 r/min
(No)
0.01-Max. rotation
speed (0.01)
Immediate value
acceleration time
5103 1h=0.1 ms
(No)
0.0-99999.9 (0.0)
Immediate
value data
Immediate value
deceleration time
5104 1h=0.1 ms
(No)
0.0-99999.9 (0.0)