CHAPTER 15 APPENDIXES
15-38
Precautions on Functions
15
15.7 Precautions on Functions
Monitor display of motor temperature
When combined with a W motor, the motor temperature is always output and displayed as 0 C° (for the
following three items).
Monitor 1 and 2 (Motor temperature output on analog monitors MON1 and MON2)
Touch panel (Motor temperature display in the monitor mode [on_24])
PC loader (Motor temperature display in the digital monitor)
Z-phase with W series motor
When using the homing function immediately after the power is supplied, perform the operation
following the conditions below if the reference signal for shift operation (PA2_11) has been set to 1:
Encoder Z-phase.
The speed must be 100 r/min or below.
Rotate the motor by the angle of rotation of 372 degrees (approx. 1.04 turn) or over with the motor
output shaft.