CHAPTER 2 WIRING
2-16
P-N Junction
2
2.2 P-N Junction
Directly connect the DC link circuit of two servo amplifiers to exchange power.
In a system having a powering (driving) shaft and regenerating (back tension) shaft such as the
winder/unwinder unit, the power consumption of the entire system can be reduced. Do not supply main
power to the servo amplifier on the other side of the P-N junction.
The capacity of the servo amplifier on the PN junction side must be equal to or less than that of the
servo amplifier on the power supply side.
■Wiring example for frame 1 ■Wiring example for frame 2 or over
For the details, contact the manufacturer.
The capacity of the servo amplifier
on the power supply side
The capacity of the servo amplifier
on the PN junction side
≧
N( - )P(+) RB1 RB2
TB2
N(-)P(+) RB1 RB2
TB2
L1
L2
L3
TB1
L1
L2
L3
TB1
N( - )P(+) RB1 RB2
TB2
RB3
N( - )P(+) RB1 RB2
TB2
RB3
L1
L2
L3
TB1
L1
L2
L3
TB1