EasyManua.ls Logo

Fuji Electric ALPHA5 Smart - Homing [ORG]: Sequence Input Signal (Reference Value 5); Homing Position LS [LS]: Sequence Input Signal (Reference Value 6)

Fuji Electric ALPHA5 Smart
636 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER 2 WIRING
2-26
Description of I/O Signals
2
Homing [ORG]: Sequence input signal (Reference value 5)
Homing position LS [LS]: Sequence input signal (Reference value 6)
A homing motion is executed and the home position is determined.
These functions are enabled only if the extension mode (parameter PA1
_
01= 6) and the positioning
operation (parameter PA1_01=7) are selected.
Function
The rising edge of the homing signal starts a homing motion. The homing motion follows the
settings of PA2_06 through PA2_18. If parameters are factory shipment settings, the following
motion is executed.
(1) After checking that the in-position signal is turned on, turn on the homing command.
(2) Once the in-position signal is turned off, you can turn off the homing command.
The motor rotates in the direction of PA2_10 (homing direction after reference signal detection) at a
speed of PA2_06 (homing speed).
(3) When the home position LS signal is turned on, the speed changes to creep speed for homing
(PA2_07).
(4) The motor moves the home position shift unit amount (PA2_14) from the first Z-phase after the
rising (or trailing) edge of the home position LS, and then it is stopped.
(5) The in-position signal is turned on with the stopping position being home position after homing
completion PA2_16. In addition, the homing completion signal is turned on.
OFF
ON
[RDY]
Zero speed
Homing [ORG]
ON
ON
Speed
OFF
Home position
LS
[
LS
]
OFF ON
Motor Z-phase
detection
In-position
[INP]
ON OFF
Homing
com
p
letion
ON/OFF
OFF
ON
ON

Table of Contents