INF-TN1FSC-E 79
10.2.2 Logger data le format
One logger le is composed of les of two types indicated below. The data le is stored as
divided by 65,500 lines for permitting high-speed access and due to restrictions in the maximum
number of lines of CSV display of Microsoft Excel.
File type File name Remarks
Con guration le (Logging name)_(date)_(hour).ini Means logger start time and relevant logger
data les.
Data le (Logging name)_(date)_(hour).csv Logging data in a speci c period
The maximum number of data les in a logger is 20 les in case of a “CONTINUOUS” logger,
and is 550 les in case of a ”SET TIME” logger. The appointed time logger is of one le per
day.
Note) After reaching the maximum data le, the logging will be stopped.
The logger data list shows the following names excluding extension (.ini) of logger con gura-
tion les.
Logger … “Logger name_(start date)_(start hour)”
Quick logger … “QUICK__(start date)_(start hour)”
If capacity shortage arises during logging operation, logging operation stops with the following
screen displayed.
When this screen appears, replace the SD memory card immediately.
Press the
ESC
key, or remove SD memory card, the message will be cleared.
Move the cursor to “STOP” to stop logging, press the
ENT
key, and once remove the memory
card.

Table of Contents