Menu #6 “Alarm Information” (
&al
) shows the causes of the past 4 alarms with an alarm code. Further, it is also
possible to display alarm information that indicates the status of the inverter when the alarm occurred. Figure 3.4-4
shows the menu transition in “Alarm Information” and Table 3.4-13 lists the details of the alarm information.
Figure 3.4-4 Menu Transition in Menu #6 “Alarm Information”
Basic key operation
To view the alarm information, set function code E52 to “2” (Full-menu mode) beforehand.
(1) Turn the inverter ON. It automatically enters Running mode in which you press the
key to switch to
Programming mode. The function selection menu appears.
(2) Use the or key to display “Alarm Information” (
&al
).
(3) Press the key to proceed to the list of alarm codes (e.g.
!0l1
).
In the list of alarm codes, the alarm information for the last 4 alarms is saved as an alarm history.
(4) Each time the or key is pressed, the last 4 alarms are displayed beginning with the most recent one in
the order of
!
,
"
,
#
and
$
(5) Press the key with an alarm code being displayed.
The item number (e.g.
6_00
) and the inverter status information (e.g. Output frequency) at the time of the
alarm occurrence alternately appear at approx. 1-second intervals.
Pressing the and keys displays other item numbers (e.g.
6_01
) and the status information (e.g. Output
current) for that alarm code.
(6) Press the key to return to the list of alarm codes. Press the key again to return to the menu.