EasyManua.ls Logo

Fuji Electric FRENIC-Ace series - Page 185

Fuji Electric FRENIC-Ace series
788 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.2 Function Codes Table
5-15
FUNCTION CODES
Chap 5
P codes: Motor 1 Parameters (Motor 1 parameter)
Code
Name Data setting range
Change when running
Data copying
Factory
Default
Drive control
Related page
V/f
PG
V/f
w/ PG
Torque control
PM
P01
Motor 1 (No. of poles)
2 to 22 poles
N
Y1
Y2
4
Y
Y
Y
Y
Y
5-148
P02
(Rated capacity)
0.01 to 1000 kW (At P99 = 0 or 4, 15)
0.01 to 1000 HP (At P99 = 1)
N
Y1
Y2
*6
Y
Y
Y
Y
Y
5-148
P03
(Rated current)
0.00 to 2000A
N
Y1
Y2
*6
Y
Y
Y
Y
Y
5-148
P04
(Auto-tuning)
0: Disable
1: Stop tuning
2: Rotation tuning
5: Stop tuning(%R1, %X) *5
N
N
0
Y
Y
Y
Y
Y
5-149
P05
(Online tuning)
0: Invalid 1: Valid
Y
Y
0
Y
Y
N
N
N
5-150
P06
(No-load current)
0.00 to 2000A
N
Y1
Y2
*6
Y
Y
Y
Y
N
5-151
P07
(%R1)
0.00 to 50.00%
Y
Y1
Y2
*6
Y
Y
Y
Y
N
P08
(%X)
0.00 to 50.00%
Y
Y1
Y2
*6
Y
Y
Y
Y
N
P09
(Slip compensation gain for
driving)
0.0 to 200.0%
Y*
Y
100.0
Y
Y
Y
N
N
5-151
P10
(Slip compensation response
time)
0.01 to 10.00 s
Y
Y1
Y2
0.5
Y
Y
N
N
N
P11
(Slip compensation gain for
braking)
0.0 to 200.0 %
Y*
Y
100.0
Y
Y
Y
N
N
P12
(Rated slip frequency)
0.00 to 15.00 Hz
N
Y1
Y2
*6
Y
Y
Y
N
N
5-152
P13
(Iron loss factor 1)
0.00 to 20.00 %
Y
Y1
Y2
*6
Y
Y
Y
Y
N
5-152
P16
(Magnetic saturation factor 1)
*5
0.0 to 300.0 %
Y
Y1
Y2
*6
N
N
Y
Y
N
5-152
P17
(Magnetic saturation factor 2)
*5
0.0 to 300.0 %
Y
Y1
Y2
*6
N
N
Y
Y
N
P18
(Magnetic saturation factor 3)
*5
0.0 to 300.0 %
Y
Y1
Y2
*6
N
N
Y
Y
N
P19
(Magnetic saturation factor 4)
*5
0.0 to 300.0 %
Y
Y1
Y2
*6
N
N
Y
Y
N
P20
(Magnetic saturation factor 5)
*5
0.0 to 300.0 %
Y
Y1
Y2
*6
N
N
Y
Y
N
P30
(PMSM drive magnetic pole
position detection mode) *5
0: Pull-in by current
1: For IPMSM (Interior permanent magnet synchronous
motor)
2: For SPMSM (Surface permanent magnet synchronous
motor)
3: Pull-in by current for IPMSM (Interior permanent
magnet synchronous motor)
N
Y1
Y2
1
N
N
N
N
Y
5-153
P53
(%X correction factor 1) *5
0 to 300 %
Y
Y1
Y2
100
Y
Y
Y
Y
N
5-153
P55
(Torque current under vector
control) *5
0.00 to 2000 A
N
Y1
Y2
*6
N
N
Y
Y
N
5-153
P56
(Induced voltage factor under
vector control) *5
50 to 100 %
N
Y1
Y2
*6
N
N
Y
Y
N
P60
(PMSM armature
resistance)*5
0.000 to 50.000 ohm
N
Y1
Y2
*7
N
N
N
N
Y
5-153
P61
(PMSM d-axis inductance)*5
0.00 to 500.00 mH
N
Y1
Y2
*7
N
N
N
N
Y
P62
(PMSM q-axis inductance)*5
0.00 to 500.00 mH
N
Y1
Y2
*7
N
N
N
N
Y
P63
(PMSM induced voltage)*5
80 to 240V (200V class); 160 to 500V (400Vclass)
N
Y1
Y2
*7
N
N
N
N
Y
P64
(PMSM iron loss)*5
0.0 to 20.0 %
Y
Y1
Y2
*7
N
N
N
N
Y
P65
(PMSM d-axis inductance
magnetic saturation
correction)*5 *9
0.0 to 100.0 % ; 999
Y
Y1
Y2
*7
N
N
N
N
Y
5-154
indicates quick setup target function code.
*5: Available at ROM version 0300 or later.
*6: Factory defaults are depended on motor capacity. Refer to 5.2.4 Motor constant”.
*7: Factory defaults are the parameters for Fuji standard PMSM and depended on motor capacity.
*9: Factory use. Do not access these function codes.

Table of Contents

Related product manuals