5.2 Function Codes Table
5-16
Code
Name Data setting range
Change when running
Data copying
Factory
Default
Drive control
Related page
V/f
PG
V/f
w/ PG
Torque control
PM
P74
(PMSM reference current at
starting)*5
10 to 200 % (100%= motor rated current)
Y*
Y1
Y2
*7
N
N
N
N
Y
5-154
P83
(Reserved for PMSM)*5 *9
0.0 to 50.0; 999
Y
Y1
Y2
999
N
N
N
N
5-154
P84
(Reserved for PMSM)*5 *9
0.0 to 100.0; 999
N
Y1
Y2
999
N
N
N
N
P85
(PMSM flux limitation value)
50.0 to 150.0; 999
Y
Y1
Y2
999
N
N
N
N
Y
5-154
P86
(Reserved for PMSM)
0.0 to 100.0%
N
N
0.0
N
N
N
N
5-154
P87
(PMSM reference current for
polarity discrimination)
0 to 200 %
N
Y1
Y2
60
N
N
N
N
Y
P88
(Reserved for PMSM)*5 *9
0 to 100 %; 999
N
Y1
Y2
999
N
N
N
N
5-154
P89
(Reserved for PMSM)*5 *9
0; 1 to 100
N
Y1
Y2
0
N
N
N
N
P90
(PMSM overcurrent protection
level)*5
0.00(disable); 0.01 to 2000 A
N
Y1
Y2
*7
N
N
N
N
Y
5-154
P99
Motor 1 selection
0: Motor characteristics 0 (Fuji standard IM, 8-series)
1: Motor characteristics 1 (HP rating IMs)
4: Other IMs
20: Other motors(PMSMs) *5
21: Motor characteristics (Fuji PMSM GNB2 series) *5
N
Y1
Y2
U:1
ACEJK:0
Y
Y
Y
Y
Y
5-154
indicates quick setup target function code.
Factory default

A (For Asia), C (for China), E (for Europe), U (For USA), J (for Japan), K (for Korea)
*5: Available at ROM version 0300 or later.
*7: Factory defaults are the parameters for Fuji standard PMSM and depended on motor capacity.
*9: Factory use. Do not access these function codes.

Table of Contents