5.2 Function Codes Table
5-17
FUNCTION CODES
Chap 5
H codes: High Performance Functions (High level function)
Code Name Data setting range
Change when running
Data copying
Factory
Default
Drive control
Related page
V/f
PG V/f
w/ PG
Torque control
PM
H02
Data initialization
(Method)
0: Standard
1: User
N
Y
0
Y
Y
Y
Y
Y
5-155
H03
(Target)
0: Manual setting value
1: Initial value (factory default value)
2: Initialize motor 1 parameters
3: Initialize motor 2 parameters
11: Initialize the parameters(excluding parameters related
to communication)
12: Initialize the parameters related to customizable logic
N
N
0
Y
Y
Y
Y
Y
H04
Auto-reset (Times)
0: Disable, 1 to 20: Number of retries
Y
Y
0
Y
Y
Y
Y
Y
5-157
H05
(Interval)
0.5 to 20.0 s
Y
Y
5.0
Y
Y
Y
Y
Y
H06
Cooling fan ON/OFF control
0: Disable (Always Fan ON)
1: Enable (ON/OFF control effective)
Y
Y
0
Y
Y
Y
Y
Y
5-158
H07
Curve acceleration/
deceleration
0: Disable (Linear acceleration/deceleration)
1: S-curve acceleration/deceleration (Weak)
2: S-curve acceleration/deceleration (Arbitrary: According
to H57 to H60)
3: Curve acceleration/deceleration
Y
Y
0
Y
Y
Y
N
Y
5-158
H08
Rotational direction limitation
0: Disable
1: Enable (Reverse rotation inhibited)
2: Enable (Forward rotation inhibited)
N
Y
0
Y
Y
Y
N
Y
5-158
H09
Starting mode (Auto search)
0: Disable
1: Enable (Only at restart after momentary power failure)
2: Enable (At normal start and at restart after
momentary power failure)
N
Y
0
Y
Y
N
N
N
5-159
H11
Deceleration mode
0: Normal deceleration 1: Coast to a stop
Y
Y
0
Y
Y
Y
N
Y
5-161
H12
Instantaneous overcurrent
limiting (Mode selection)
0: Disable 1: Enable
Y
Y
1
Y
Y
N
N
N
5-161
H13
Restart mode after momentary
power failure (Restart timer)
0.1 to 20.0 s
Y
Y1
Y2
*2
Y
Y
Y
N
N
5-161
H14
(Frequency fall rate)
0.00: Selected deceleration time, 0.01 to 100.00Hz/s,
999 (According to current limiter)
Y
Y
999
Y
Y
N
N
N
H15
(Continuous running level)
200 to 300V: (200 V class)
400 to 600V: (400V class)
Y
Y2
235
470
Y
Y
Y
N
Y
H16
(Allowable momentary power
failure time)
0.0 to 30.0s, 999 (Depend on inverter judgment)
Y
Y
999
Y
Y
Y
N
Y
H18
Torque control *5
(Mode selection)
0: Disable (Speed control)
2: Function (Torque current command)
3: Function (Torque command)
N
Y
0
N
N
Y
Y
N
5-162
H26
Thermistor (for motor)
(Mode selection)
0: Disable
1: PTC:
0h4
trip and stop the inverter
2: PTC: Output motor overheat detected THMand
continue to run
Y
Y
0
Y
Y
Y
Y
Y
5-164
H27
(Level)
0.00 to 5.00 V
Y
Y
1.60
Y
Y
Y
Y
Y
H28
Droop control
-60.0 to 0.0Hz
Y
Y
0.0
Y
Y
Y
N
N
5-166
H30
Communication link function
(Mode selection)
0:
1:
2:
3:
4:
5:
6:
7:
8:
Frequency command
F01/C30
RS-485 (Port 1)
F01/C30
RS-485 (Port 1)
RS-485 (Port 2)
RS-485 (Port 2)
F01/C30
RS-485 (Port 1)
RS-485 (Port 2)
Run command
F02
F02
RS-485 (Port 1)
RS-485 (Port 1)
F02
RS-485 (Port 1)
RS-485 (Port 2)
RS-485 (Port 2)
RS-485 (Port 2)
Y
Y
0
Y
Y
Y
Y
Y
5-167
H42
Capacitance of DC link bus
capacitor
For adjustment at replacement
(0000 to FFFF (in hexadecimal))
Y
N
Y
Y
Y
Y
Y
5-169
H43
Cumulative run time of cooling
fan
For adjustment at replacement Displays the cumulative run
time of cooling fan in units of ten hours.
Y
N
Y
Y
Y
Y
Y
H44
Startup count for motor 1
For adjustment at replacement
(0000 to FFFF in hexadecimal)
Y
N
Y
Y
Y
Y
Y
5-173
H45
Mock alarm
0: Disable
1: Occurrence of mock Alarm
Y
N
0
Y
Y
Y
Y
Y
5-173
H46
Starting mode
(Auto search delay time 2)
0.1 to 20.0 s
Y
Y1
Y2
*6
Y
Y
N
N
Y
5-173
*2: Factory defaults are depended on motor capacity. Refer to 5.2.3 Factory default value per applicable electric motor capacitance”.
*5: Available at ROM version 0300 or later.
*6: Factory defaults are depended on motor capacity. Refer to 5.2.4 Motor constant”.