5.3 Description of Function Codes
5-237
FUNCTION CODES
Chap 5
Hold line speed control frequency in the memory -- “LSC-HLD(Function code E01 to E05, data = 71)
If “LSC-HLDis turned ON under line speed control, stopping the inverter (including an occurrence of an alarm
and a coast-to-stop command) or turning Hz/LSC” ON saves the current frequency command compensating for a
take-up roll getting bigger, in the memory. At the time of restart, the saved frequency command applies and the
inverter keeps the line speed constant.
“LSC-HLD
Function
OFF Disable (No saving operation)
ON Enable (Saving the frequency command compensating for a take-up roll getting bigger)
Shutting down the inverter power during operation stop loses the frequency compensation data saved in
the memory. At the time of restart, therefore, the inverter runs at the frequency without compensation so
that a large overshoot may occur.
d51, d52
d55, d69,
d79, d88
d91 to d97
Reserved for particular manufacturers
These function codes are reserved for particular manufacturers. Unless otherwise specified, do not access these
function codes.
d60
Command (Pulse train input) (Encoder pulse resolution)
d60 specifies the pulse resolution (P/R) of the command pulse.
Data setting range: 20 to 3600 (P/R), Set by standard keypad in hexadecimal format (0x0014 to 0x0E10)
d61 to d63
Command (Pulse train input)
(Filter time constant, Pulse scaling factor 1 and Pulse scaling factor 2) (Refer to F01.)
Refer to the description of the function code F01 for details on the pulse rate input.
d67
PMSM starting mode (Auto search)
Refer to the description of the function code H09 for details on the PMSM starting mode.