5.3 Description of Function Codes
5-255
FUNCTION CODES
Chap 5
Operation of general-purpose timer(Digital)
The operation schemes for individual timers are shown below.
(End 1) On-delay timer
OFF ON
Timer
Input
Output
Time setting value
OFF
ON
OFF
ON OFFOFF
(End 2) Off-delay timer
OFF
ON
Timer
Input
Output
Time setting value
OFF ON
OFF
OFF
ON ON
ON
OFF
(End 3) One-shot pulse output
OFF ON
Timer
Input
Output
Time setting value
OFF
OFF ON ON
OFF
OFF OFF
(End 4) Retriggerable timer
OFF
ON
Timer
Input
Output
Time setting value
OFF
OFF ON
ON
OFF
OFF
OFF
ON
ON
10.00 s
Time setting value
Equal or less than time setting value
(End 5) Pulse train output
OFF
ON
Timer
Input
Output
Time setting value
OFF
ON ON
OFF
OFF
OFF
ON
ON

Table of Contents