5.3 Description of Function Codes
5-256
■ Inputs 1 and 2 (U02, U03, etc.)(Digital)
The following digital signals are available as input signals. Value in ( ) is in negative logic.
Data Selectable Signals
0000 (1000) General-purpose output signals Same as the ones specified by E20, e.g., “RUN” (Inverter
running), FAR (Frequency (speed) arrival signal), “FDT” (Frequency (speed) detected),
“LU” (Undervoltage detected (Inverter stopped)), “B/D” (Torque polarity detected)
Note: 27 (Universal DO) is not available.
Note: Customizable logic output signals from 111 (1111) to 120 (1120) cannot be selected.
to
0105 (1105)
2001 (3001) Output of step 1 “SO01”
to to
2200 (3200) Output of step 200 “SO200”
4001 (5001) Terminal X1 input signal “X1”
4002 (5002) Terminal X2 input signal “X2”
4003 (5003) Terminal X3 input signal “X3”
4004 (5004) Terminal X4 input signal “X4”
4005 (5005) Terminal X5 input signal “X5”
4010 (5010) Terminal FWD input signal FWD
4011 (5011) Terminal REV input signal REV
4021 (5021) Terminal I1 input signal “I1” (on option card, OPC-DIO)
4022 (5022) Terminal I2 input signal “I2” (on option card, OPC-DIO)
4023 (5023) Terminal I3 input signal “I3” (on option card, OPC-DIO)
4024 (5024) Terminal I4 input signal “I4” (on option card, OPC-DIO)
4025 (5025) Terminal I5 input signal “I5” (on option card, OPC-DIO)
4026 (5026) Terminal I6 input signal “I6” (on option card, OPC-DIO)
4027 (5027) Terminal I7 input signal “I7” (on option card, OPC-DIO)
4028 (5028) Terminal I8 input signal “I8” (on option card, OPC-DIO)
4029 (5029) Terminal I9 input signal “I9” (on option card, OPC-DIO)
4030 (5010) Terminal I10 input signal “I10” (on option card, OPC-DIO)
4031 (5011) Terminal I11 input signal “I11” (on option card, OPC-DIO)
4032 (5012) Terminal I12 input signal “I12” (on option card, OPC-DIO)
4033 (5013) Terminal I13 input signal “I13” (on option card, OPC-DIO)
6000 (7000) Final RUN command “FL_RUN” (ON when a run command is given)
6001 (7001) Final FWD run command “FL_FWD” (ON when a run forward command is given)
6002 (7002) Final REV run command “FL_REV” (ON when a run reverse command is given)
6003 (7003) During acceleration “DACC” (ON during acceleration)
6004 (7004) During deceleration “DDEC” (ON during deceleration)
6005 (7005) Under anti-regenerative control “REGA” (ON under anti-regenerative control)
6006 (7006) Within dancer reference position “DR_REF” (ON when the dancer position is within the
reference range)
6007 (7007) Alarm factor presence “ALM_ACT” (ON when there is no alarm factor)