5.3 Description of Function Codes 5.3.2 E codes (Extension terminal functions)
5-179
FUNCTION CODES
Chap 5
FUNCTION
CODES
F Codes
E Codes
C Codes
P Codes
H Codes
A Codes
b Codes
r Codes
J Codes
d Codes
U Codes
y Codes
K Codes
E44
LED monitor (display when stopped)
Selects monitor information displayed with the keypad LEDs while the inverter is stopped. If E44 = 0, the set
frequency is displayed, and when E44 = 1, the output frequency is displayed. The display format is that selected
with Speed monitor E48.
E48 data
Monitored item
Inverter stopped
E44 = 0 Specified value
E44 = 1 Output value
0
Output frequency 1
(before slip
compensation)
Reference frequency
Output frequency 1
(before slip compensation)
1
Output frequency 2
(after slip
compensation)
Reference frequency
Output frequency 2
(after slip compensation)
2
Reference
frequency
Reference frequency
Reference frequency
3
Motor rotation
speed
Reference motor rotation speed
Motor rotation speed
4
Load rotation speed
Reference load rotation speed
Load shaft speed
5
Feed speed
Reference line speed
Line speed
6
Transport time for
specified length
Transport time for specified
length setting
Constant feeding rate time
7
Speed (%)
Reference display speed
Display Speed
8
Line speed set
value
9
Line speed output
value
E48
LED monitor (speed monitor item) (Refer to E43)
For details about LED Monitor (Speed monitor item), refer to the description of E43.