5.3 Description of Function Codes 5.3.5 H codes (High performance functions)
5-254
Passwords 1, 2 temporary disabling failure
In password 1 protective status or password 2 protective status, if the password value entered in function code
H198 or H99 is incorrect when trying to temporarily cancel the protective status, temporary decoding is disabled.
In both function codes H198 and H99, 5 consecutive failures of password input result in a warning.
Password temporary
decoding
(Function code read
enable)
Set the password to function code
H99.
Password protection
(Function code read/write
disable)
Set 1 to function code H199 or the specified
period of time has passed after temporary
decoding of the password.
Set the correct password to
function code H99.
Set incorrect passwords to
function code H99. (Less than
5 times)
Password
Protection + Occurrence
of minor failure (Function code
read/write disable)
(Inverter operation
enable)
Set incorrect passwords to
function code H99. (5 times)
Password
Protection + Occurrence
of LoK alarm (Function code
read/write disable)
(Inverter operation
disable)
Password not set
(Function code read enable)
After 20 minutes,
release the minor
failure.
Perform data initialization
[H03=1] with Fuji Electric
standard initial value [H02=0].
Set incorrect passwords
to function code H99.
(No. of specified times).
Perform data initialization
[H03=1] with Fuji Electric
standard initial value
[H02=0].
Fig. 5.3-31 Relation chart of password 2 protection status
In our factory default status, passwords are not provided excluding special products. Therefore, if the
password set for H198 or H99 is unknown or forgotten, we do not answer or inform you of the password
or its decoding method from protective status.
For this reason, set and control the password at your own risk. If a password is set at the delivery of the
product and its decoding is required, please contact the dealer you purchased or the unit manufacturer.
(We are not able to know the passwords set by customers.)
Setting and temporary disabling of password 1, 2 using multi-function keypad
Setting or temporary decoding of passwords 1 and 2 using the multi-function keypad is performed by the special
menu on the multi-function keypad. Therefore, function codes H99H198 and H199 are not displayed on the
function code list of the function code setting menu or function code check menu on the multi-function keypad (H197
is displayed).
For the special password menu of the multi-function keypad, refer to the instruction manual of the multi-
function keypad.