5.3 Description of Function Codes 5.3.8 J codes (Applied functions)
5-290
Dedicated reverse rotation brake signal function codes
If necessary to make individual adjustments with forward rotation or reverse rotation, do so with the following
dedicated reverse rotation function codes. If data = 999 (factory default), operation will be performed with the J code
function code setting value.
Function code
Name
Data setting range
Remarks
d120
Brake-release
current
0.00 to 300.00%, 999: operation based
on J68 setting value
100% = inverter rated
current
d121
Brake-release
frequency/speed
0.0 to 25.0 Hz, 999: operation based on
J69 setting value
d122
Brake-release timer
0.000 to 5.000 s, 999: operation based
on J70 setting value
d123
Brake-release
torque
0.00 to 300.00%, 999: operation based
on J95 setting value
100% = motor rated torque
d124
Brake-apply
frequency/speed
0.0 to 25.0 Hz, 999: operation based on
J71 setting value
d125
Brake-apply timer
0.000 to 5.000 s, 999: operation based
on J72 setting value