5.3 Description of Function Codes 5.3.10 U codes (Customizable logic operation)
5-384
(Data=6□) Reset priority flip-flop
OutputInput 1
Input 2
General-purpose timer
S Q
R
Flip-flop
(Data=7□) Rising edge detector (Data=8□) Falling edge detector (Data=9□)
Rising & falling edges detector
Output
Input 1
Input 2
General-purpose timerRising edge detector
OutputInput 1
Input 2
General-purpose timerFalling edge detector
Output
Input 1
Input 2
General-purpose timerRising & falling edges detector
(Data=10□) Hold (Data=110) Increment counter (Data=120) Decrement counter
Output
Input 1
Input 2
General-purpose timer
= 0
= 1
Output
Input 1
Input 2
Increment counter
Count cleared
Output
Input 1
Input 2
Decrement counter
Count initialized
(Data=130) Timer with reset input
(Data=14□) D flip-flop (Data=15□) T flip-flop
OutputInput 1
Input 2
General-purpose timer
S Q
R
Flip-flop
OutputInput 1
Input 2
General-purpose timer
S Q
R
Flip-flop
Output
Input 1
Input 2
ON Timer
Reset
Timer
Output
Time setting
ON
OFF
OFF
OFF
ON
Input 1
Input 2
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Input 1
Input 2
Previous
output
Output
Remarks
OFF
OFF
OFF
OFF
Hold previous
value
ON
ON
-
ON
-
OFF
Reset priority
ON
OFF
-
ON
U05: Output initial status
(0 initial status ON)
D
CL
T
U05: Output initial status
(0 initial status ON)
U05: Output initial status
(0 initial status ON)