5.3 Description of Function Codes 5.3.10 U codes (Customizable logic operation)
Terminal [CLI7] input “CLI7”
Terminal [CLI8] input “CLI8”
Terminal [CLI9] input “CLI9”
Logic operations can be performed and stopped when triggered by keypad button
operations.
Keypad RUN/FWD key “KP-RUN/KP-FWD”
Keypad STOP key "KP-STOP"
Keypad DOWN key "KP-DOWN"
Keypad M/SHIFT key "KP-M/SHIFT"
Keypad RESET key "KP-RESET"
Terminal [X1] input (terminal block only) “X1-TERM”
Terminal [X2] input (terminal block only) “X2-TERM”
Terminal [X3] input (terminal block only) “X3-TERM”
Terminal [X4] input (terminal block only) “X4-TERM”
Terminal [X5] input (terminal block only) “X5-TERM”
Terminal [X6] input (terminal block only) “X6-TERM”
Terminal [X7] input (terminal block only) “X7-TERM”
Terminal [X8] input (terminal block only) “X8-TERM”
Terminal [X9] input (terminal block only) “X9-TERM”
Terminal [FWD] input (terminal block only) “FWD-TERM”
Terminal [REV] input (terminal block only) “REV-TERM”
Final RUN command “FL_RUN” (ON when a run command is given)
Final FWD run command “FL_FWD” (ON when a run forward command is given)
Final REV run command “FL_REV” (ON when a run reverse command is given)
During acceleration “DACC” (ON during acceleration)
During deceleration “DDEC” (ON during deceleration)
Under anti-regenerative control “REGA” (ON under anti-regenerative control)
Within dancer reference position “DR_REF” (ON when the dancer position is within
the reference range)
Alarm factor presence “ALM_ACT” (ON when there is no alarm factor)
TRUE (1) fixed input “TRUE”: always ON No logic inversion
FALSE (0) fixed input “FALSE”: always OFF No logic inversion
Function 1 (U04 etc.)
U04 and other related function codes specify the general-purpose timer period or the increment/decrement counter
value.
The period is specified in seconds.
The specified value is multiplied by 100 times.
(If 0.01 is specified, it is converted to 1.)
The timer or counter value works as 0.00. (No timer)
The period is specified in seconds.