If a step output is digital
The same value as E98 can be specified.
0 (1000): Select multistep frequency (0 to 1 steps)
“SS1”
1 (1001): Select multistep frequency (0 to 3 steps)
“SS2”
2 (1002): Select multistep frequency (0 to 7 steps)
“SS4”
3 (1003): Select multistep frequency (0 to 15
steps)
“SS8”
4 (1004): Select ACC/DEC time (2 steps) “RT1”
5 (1005): Select ACC/DEC time (4 steps) “RT2”
6 (1006): Select 3-wire operation “HLD”
7 (1007): Coast to a stop command “BX”
8 (1008): Reset alarm (Abnormal) “RST”
9 (1009): Enable external alarm trip “THR”
(9=Active OFF/1009=Active ON)
etc.
If a user-defined alarm occurs with step
output
241 (1241): User-defined alarm 1 “Ca1”
242 (1242): User-defined alarm 2 “Ca2”
243 (1243): User-defined alarm 3 “Ca3”
244 (1244): User-defined alarm 4 “Ca4”
245 (1245): User-defined alarm 5 “Ca5”
If a step output is analog
8001: Auxiliary frequency setting 1
8002: Auxiliary frequency setting 2
8003: PID command
8005: PID feedback value
8006: Ratio setting
8007: Analog torque limiter A
8008: Analog torque limit value B
8009: Analog torque bias
8010: Analog torque command
8011: Analog torque current command
8012: Acceleration/deceleration time ratio setting
8013: Upper limit frequency
8014: Lower limit frequency
8015: Auxiliary frequency setting 3
8016: Auxiliary frequency setting 4
8017: Analog speed limit for forward rotation
8018: Analog speed limit for reverse rotation
8020: Analog monitor