Chapter 8 SPECIFICATIONS
8.1 Standard Models
8.1.1 Three-phase 200 V class series
Item Specifications
Type (FRN_ _ _ _ C2S-2U) 0025 0033 0047 0060
Applicable motor rating (HP) *1
7.5 10 15 20
Rated capacity (kVA) *2 9.5 12 17 22
Rated voltage (V) *3 Three-phase, 200 to 240 V (with AVR function)
Rated current (A)
25
(23.5) *10
33.0
(31.0) *10
47.0
(44.0) *10
60.0
(57.0) *10
Overload capability
150% of rated output current for 1 min or 200% of rated output
current for 0.5 min
Output Ratings
Rated frequency (Hz) 50 60 Hz
Phases, voltage, fre-
quency
Three-phase, 200 to 240 V, 50/60 Hz
Voltage and frequency
variations
Voltage: +10 to -15% (Interphase voltage unbalance: 2% or less)
*5, Frequency: +5 to -5%
(w/ DCR) 21.1 28.8 42.2 57.6
Rated cur-
rent (A) *6
(w/o DCR) 31.5 42.7 60.7 80.0
Input Ratings
Required power supply
capacity (kVA) *7
7.4 10 15 20
Torque (%) *8 20
DC braking
Braking starting frequency*9: 0.0 to 60.0 Hz,
Braking time: 0.0 to 30.0 s, Braking level: 0 to 100%
Braking
Braking transistor Built-in
Applicable safety standards UL508C, IEC 61800-5-1: 2007 (under application)
Enclosure IP20 (IEC 60529:1989), UL open type (UL50)
Cooling method Fan cooling
Mass (lbs)
6.8 6.8 9.8 9.8
*1 Fuji 4-pole standard motors
*2 Refers to the rated capacity assuming the rated output voltage as 220 V for three-phase 200V series.
*3
Output voltages cannot exceed the power supply voltag
e.
*5
2004):3-61800IECto(Refer67
(V)voltageaveragephase-3
(V)eMin.voltag-(V)voltageMax.
(%)unbalancevoltageInterphase
If this value is 2 to 3%, use an optional AC reactor (ACR).
*6 Refers to the estimated value to apply when the power supply capacity is 500 kVA (inverter capacity x 10 when the
inverter capacity exceeds 50 kVA) and the inverter is connected to the %X = 5% power supply.
*7 Refers to the value to apply when a DC reactor (DCR) is used.
*8 Refers to the average braking torque to apply when the motor running alone decelerates from 60 Hz with the AVR
control being OFF. (It varies with the efficiency of the motor.)
*9 Available only for induction motor drive.
*10The load shall be reduced so that the continuous operating current is the rated current in parentheses or less if the
carrier frequency is set to 4 kHz or above or the ambient temperature exceeds 40°C
104°F .