5 Selectin
Function 5-17
FVR-C11S-EN
5
Chan
e durin
operation: X = impossible, = possible (enabled b
usin
), = possible (enabled b
usin
)
Coast-to-stop command (BX)
Inverter output is cut when the BX ter-
minal is connected to the P24/CM ter-
minal.
OFF input is assumed when BX is not
selected.
Alarm reset (RST)
The alarm output is released between
the RST and P24/CM terminals when
power is turned on.
The trip status is released between the
RST and P24/CM terminals when pow-
er is turned off.
(Refer to 6-2 Alarm Reset on pa
e 6-3)
External alarm (THR)
Inverter trips with OH2 when the THR
terminal is disconnected from the P24/
CM terminal.
ON input is assumed when THR is not
selected.
Write enable command for ke
pad
(WE-KP)
Function chan
e from the ke
pad panel
is disabled when the WE-KP terminal is
disconnected from the P24/CM termi-
nal.
Function chan
e from the ke
pad panel
is enabled when the WE-KP terminal is
connected to the P24/CM terminal.
ON input is assumed when WE-KP is
not selected.
PID control cancel (Hz/PID)
PID control operates when the Hz/PID
terminal is disconnected from the P24/
CM terminal and does not operate
when the
are connected.
OFF is assumed when the Hz/PID is
not selected.
Hz/PID is valid onl
when function
is set to or .
(PID control operation).
Link operation selection (LE)
Operation settin
can be done b
com-
mands from RS485 when the LE termi-
nal is connected to the P24/CM
terminal.
A command from RS485 is i
nored
when the LE terminal is disconnected
from the P24/CM terminal.
ON input is assumed when LE is not se-
lected.
LE is valid onl
when function is
set to (option operation).
2
3
4
5
6
H20 1 2
7
o00
1