Loading...
7 Troubleshootin
7-12
FVR-C11S-EN
7
5) When function chan
g
e disabled
Function chan
g
e is
disabled.
An
y
of E01, E02, E03
set to 5?
Yes
Short-circuit between
terminals X1,X2,X3
correspondin
g
to
function set to 5 and
P24/CM terminal.
No
F00 set to 0?
No
Set F00 to 0.
Yes
Attempt made to
chan
g
e an
unchan
g
eable function
durin
g
operation?
Yes
Chan
g
e function after
stoppin
g
inverter.
No
Function to be chan
g
ed
F00 or H03?
Yes
Press STOP ke
y
and
UP or DOWN ke
y
simultaneousl
y
.
No
Function to be chan
g
ed
F02?
FWD or REV
terminal connected to
P24/CM terminal?
Yes
Open FWD and REV
command.
No
Function to be chan
g
ed
F05, F06, F24, H01 or
H02?
Yes
Chan
g
e other
functions.
No
Contact Fuji Electric.