8 Maintenance and Inspection 8-4
FVR-C11S-EN
8
Table 8-2-1 Periodic inspection list
Check part Check item How to inspect Evaluation criteria
Control circuit
Control
PC board
and
connector
1. Loose screws or connec-
tors?
2. Unpleasant smell or
discoloration?
3. Cracks, dama
e, deforma-
tion, or excessive rust?
4. Electrol
te leaka
e or a
deformed mark on the
capacitor?
1. Ti
hten more.
2. Olfactor
and
visual inspection
3., 4. Visual
inspection
1., 2., 3., 4.
Not abnormal.
Cooling system
Coolin
fan
(1.5 kW
minimum)
1. Abnormal sound or
vibration?
2. Loose of bolts?
3. Discoloration
b
overheatin
?
1. Aural and visual
inspection. Turn
with hand. (Make
sure power is off)
2. Ti
hten more
3. Visual inspection
1. The fan must rotate
smoothl
.
2., 3. Not abnormal
Ventila-
tion wa
Clo
in
-up or forei
n sub-
stance on heat sink or intake/
exhaust ports?
Visual inspection Not abnormal
Note: Use a capacitance measurin
instru-
ment available on the market which is
eas
to use.
Remark: If the equipment is stained, wipe it with
a cleanin
cloth, which is chemicall
neutral.
Vacuum-clean the dust.