15.2 Temperature Controller/Servo/Inverter Connection 15-65
KW7M
(Underlined setting: default)
Stop bit: 1 (fixed)
Available Device Memory
The available setting range of device memory varies depending on the model. Be sure to set within the range available for the
model to be used. Use [TYPE] when assigning indirect device memory for macro programs.
PLC_CTL
Macro command “PLC_CTL F0 F1 F2
Return data: Data stored from Eco-POWER METER to V series
Mode Display Item Setting
MODE 2
PROT Protocol setting mode MEWT: MEWTOCOL
NO. Station number setting mode 1 to 99
SPD Baud rate setting mode
4800: 4800 bps
9600: 9600 bps
19200: 19200 bps
38400: 38400 bps
FMT
Communication format
setting mode
8bit-o: data length 8 bits, odd parity
7bit-n: data length 7 bits, without parity
7bit-E: data length 7 bits, even parity
7bit-o: data length 7 bits, odd parity
8bit-n: data length 8 bits, without parity
8bit-E: data length 8 bits, even parity
Device Memory TYPE Remarks
DT (data register) 00H
Contents F0 F1 (=$u n) F2
Status read
1 to 8
(PLC1 to 8)
n Station number: 1 to 99
2
n+1 Command: 0000H
n+2 Model code 1
n+3 Model code 2
n+4 Version
n+5
Operation mode
0: Stopped
1: Running
n+6
Error flag
0: Normal
1: Error
n+7 Self-diagnosis error number