5-2. Outdoor unit
¢ Discharge temperature thermistor
Temperature (°C) Resistance (kΩ) Voltage (V)
-30.0 1,013.1 0.06
-25.0 729.1 0.09
-20.0 531.6 0.12
-15.0 392.3 0.16
-10.0 292.9 0.21
-5.0 221.1 0.28
0.0 168.6 0.36
5.0 129.8 0.46
10.0 100.9 0.57
15.0 79.1 0.71
20.0 62.5 0.86
25.0 49.8 1.03
30.0 40.0 1.23
35.0 32.4 1.43
40.0 26.3 1.65
45.0 21.6 1.88
50.0 17.8 2.11
55.0 14.8 2.34
60.0 12.3 2.57
65.0 10.3 2.79
70.0 8.7 3.00
75.0 7.4 3.19
80.0 6.3 3.37
85.0 5.4 3.54
90.0 4.6 3.69
95.0 4.0 3.83
100.0 3.4 3.96
105.0 3.0 4.07
110.0 2.6 4.17
115.0 2.3 4.26
120.0 2.0 4.33
5-2. Outdoor unit - (03-44) - 5. Thermistor resistance values