4. AIRFLOW SETTINGS
NOTE:
For detailed instructions on how to operate, refer to the
operation manual of the remote controller.
4.1. Fan speed setting
Fan speed Description
Auto
The fan speed is automatically adjusted according to
the operation mode.
Cooling : As the room temperature approaches the


set temperature, the fan speed becomes
lower.
Heating : The fan will operate at a very low speed
when the temperature of the air issued
from the indoor unit is low.
Fan : The fan runs at Med speed.
High The indoor unit fan rotates at a high speed.
Med The indoor unit fan rotates at a middle speed.
Low The indoor unit fan rotates at a low speed.
Quiet
The indoor unit fan rotates at the lowest speed for
Quiet operation.
The Quiet operation cannot be used during
the Dry mode. (It includes the Dry mode selected
during the Auto mode operation.)
During the Quiet operation, heating and
cooling performance will be reduced somewhat. If
the room does not warm up/ cool down when using
the Super Quiet operation, adjust the indoor unit’s
fan speed.
The fan will operate at a very low setting during monitor operation and
at the start of the heating mode.
4.2. Air ow direction setting
You can set the following items.
• Up/down air ow direction setting
Swing operation setting (up/down)
NOTE:
The Swing operation may stop temporarily when the indoor unit
fan is rotating at a very low speed or is stopped.
Up/down air ow direction
Comfortable air ow spread to every corner of the room by the
wide up/down air ow.
3. BASIC OPERATIONS
NOTE:
For detailed instructions on how to operate, refer to the
operation manual of the remote controller.
The operation mode and the temperature setting range are
shown in the following table.
Operation mode Temperature setting range
Auto/Cooling/Dry 18.0 - 30.0 °C
Fan You cannot set the temperature.
Heating 16.0 - 30.0 °C
Auto mode
The air conditioner selects the appropriate operation mode
(Cooling or Heating) according to your room’s present
temperature.
Room temperature Operation
Higher than the setting temperature Cooling
Close to the setting temperature Monitor operation
Lower than the setting temperature Heating
Set temperature
Monitor operation
Cooling mode
Heating mode
When Auto mode is rst selected, the fan will operate at low speed for
about a few minutes, during which time the indoor unit detects the room
conditions and selects the operation mode.
When the air conditioner has adjusted your room’s temperature to near
the thermostat setting, it will begin the monitor operation.
In the monitor operation mode, the fan will operate at low speed. If the
room temperature subsequently changes, the air conditioner will once
again select the appropriate operation (Heating, Cooling) to adjust the
temperature to the value set in the thermostat.
If the mode automatically selected by the unit is not what you wish,
select one of the mode operations (Heating, Cooling, Dry, Fan).
Cooling mode
Use to cool your room.
NOTE:
Set the temperature lower than the current room temperature,
otherwise, the fan alone will operate.
Dry mode
Use for gently cooling while dehumidifying your room.
NOTES:
You cannot heat the room.
Set the temperature lower than the current room temperature,
otherwise, the operation will not operate.
The unit will operate at low speed in order to adjust room humidity.
The indoor unit’s fan may stop from time to time. Also, the fan may
operate at a very low speed when adjusting room humidity.
The fan speed cannot be changed manually.
Fan mode
Use to circulate the air throughout your room.
NOTE:
You cannot set the temperature.
Heating mode
Use to warm your room.
NOTES:
Set the temperature higher than the current room temperature,
otherwise, the operation will not operate.
At the beginning of the operation, the indoor unit fan rotates at a
very low speed for 3-5 minutes to warm the internal indoor unit. After
the period, the indoor unit fan will switch to the selected fan speed.
When the room temperature is very low, frost may form on the
outdoor unit, and its performance may be reduced. In order to
remove such frost, the unit will automatically enter the defrost cycle
from time to time. During the Automatic defrosting operation, the
Heating operation will be interrupted.
After the start of the Heating operation, it takes some time before
the room gets warmer.