01-04
AUU12RML
Operation mode Air flow mode
Speed (rpm)
Hi 660
580
520
460
Me
Lo
Dry
Monitoring
Quiet
Hi
Me
Lo
Quiet
650
580
Me+
620
520
460
460
300
Auto
S- Lo
Cooling
Fan
Heating
AUU9RML
Operation mode Air flow mode
Speed (rpm)
Hi 590
540
490
440
Me
Lo
Dry
Monitoring
Quiet
Hi
Me
Lo
Quiet
590
540
Me+
570
490
440
460
300
Auto
S- Lo
Cooling
Fan
Heating
Operation mode Air flow mode
Speed (rpm)
Hi 790
660
570
460
Me
Lo
Dry
Monitoring
Quiet
Hi
Me
Lo
Quiet
840
750
Me+
800
650
500
460
300
Auto
S- Lo
Cooling
Fan
Heating
AUU18RML
(2).FAN OPERATION
The airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH, while the indoor
fan only runs.
When Fan mode is set at (Auto), it operates on (MED) Fan Speed. < for AS, AU type >
it operates intermittent on (LO) Fan speed and (OFF)
by one minute. <for AR type>
(3). COOLING OPERATION
(Fig.2)
airflow change - over ( Cooling: AUTO )
When the room
temperature rises
Lo mode
When the room
temperature lowers
Hi mode
Me mode
*(
*
*1
*1 : Contains a condition to the following
When the operation mode is set to AUTO mode
at the start of operation.
When the setting temperature was changed.
When the operation mode was changed to COOLING mode.
When the airflow mode was changed to AUTO mode.
Switch the airflow [AUTO], and the indoor fan motor will run according to a room temperature,
as shown in Figure 2.
On the other hand, if switched in [HIGH] [QUIET], the indoor motor will run at a constant airflow of [COOL]
operation modes QUIET, LOW, MED, HIGH,as shown in Table 2.
*For AS / AU / Type
+4°F(+2°C)
+2°F(+1°C)
+5°F(+2.5°C))
+3°F(+1.5°C)
(+3°F ) (+1.5°C)
+6°F(+3.0°C)
(Room temperature) D (Setting temperature)