Type
Wall mounted
Inverter heat pump
Model name ASUH09LPAS ASUH12LPAS
Remote controller type
Wireless (Wired, Mobile app*
5
[FGLair
] [option])
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 80°FDB (26.67°CDB)/67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB)/75°FWB (23.9°CWB).
Heating: Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 47°FDB (8.33°CDB)/43°FWB (6.11°CWB).
*1: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 17°FDB (-8.33°CDB)/15 °FWB (-9.44°CWB).
*2: Heating (5°F): Indoor temperature of 70°FDB (21.11°CDB)/60°FWB (15.56°CWB), and outdoor temperature of 5°FDB (-15.0°CDB)/4°FWB (-15.56°CWB).
Test conditions are based on AHRI 210/240 2023.
Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*3: Maximum current is maximum value when operated within the operation range.
*4: Sound pressure level:
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
*5: Available on Google Play
store or on App Store
®
. Optional WLAN Adapter is also required. For details, refer to the setting manual.
M condition
Model name ASUH09LPAS ASUH12LPAS
Capacity
Cooling
Rated
kW 2.64 3.52
Btu/h 9,000 12,000
Min.—Max.
kW 0.97—3.16 1.00—3.72
Btu/h 3,300—10,800 3,400—12,700
Heating
Rated
kW 2.93 4.10
Btu/h 10,000 14,000
Min.—Max.
kW 0.77—3.66 0.91—4.98
Btu/h 2,600—12,500 3,100—17,000
Heating (17°F)*
Rated
kW 1.82 2.58
Btu/h 6,200 8,800
Max.
kW 2.49 3.34
Btu/h 8,500 11,400
Input power
Cooling
Rated
kW
0.72 1.09
Min.—Max. 0.14—1.18 0.14—1.33
Heating
Rated 0.74 1.10
Min.—Max. 0.13—1.23 0.14—1.61
Heating (17°F)*
Rated 0.65 0.85
Max. 1.09 1.34
Current
Cooling
Rated A
3.5 4.9
Heating 3.7 4.9
EER Cooling
kW/kW 3.66 3.22
Btu/hW 12.5 11.0
COP Heating
kW/kW 3.96 3.72
Btu/hW 13.50 12.70
SEER Cooling Btu/hW 20.0
HSPF Heating Btu/hW 11.0
Power factor
Cooling
%
89.4 96.7
Heating 86.9 97.6
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 80°FDB (26.67°CDB)/67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB)/75°FWB (23.9°CWB).
Heating: Indoor temperature of 70°FDB (21.11°CDB)/59°FWB (15.56°CWB), and outdoor temperature of 47°FDB (8.33°CDB)/43°FWB (6.11°CWB).
*: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB) /60°FWB (15.56°CWB), and outdoor temperature of 17°FDB (-8.33°CDB)/15°FWB (-9.44°CWB).
Test conditions are based on AHRI 210/240 2017.
Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
- 3 -
1. Specifications
WALL MOUNTED
ASUH09-12LPAS
WALL MOUNTED
ASUH09-12LPAS