EasyManua.ls Logo

Fujitsu AOUH18LPAS1 - Page 71

Fujitsu AOUH18LPAS1
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Multiple outdoor unit installation
Provide at least 10 in (250 mm) of space between the outdoor units if multiple units are in-
stalled.
When routing the piping from the side of an outdoor unit, provide space for piping.
No more than 3 units must be installed side by side.
When 4 units or more are arranged in a line, provide the space as shown in the following ex-
ample “When an obstruction in the upper space:”.
When the upper space is open:
Unit: in (mm)
Obstacles at rear only Obstacles at front only
10 (250) or more
8 (200)
or more
10 (250) or mo
r
e
40 (1,000)
or more
Obstacles at front and rear
10 (250) or more
8 (200) or more
40 (1,000) or more
When an obstruction in the upper space:
Unit: in (mm)
Obstacles at rear and above.
10 (250)
or more
10 (250)
or more
60 (1,500)
or more
60 (1,500)
or more
8 (200) or more
Max. 11 (300)
- 67 -
3-1. Models: AOUH18LPAS1 and AOUH24LPAS1 3. Installation space
OUTDOOR UNIT
AOUH18-24LPAS1
OUTDOOR UNIT
AOUH18-24LPAS1

Other manuals for Fujitsu AOUH18LPAS1

Related product manuals