1) Remote controller address setting
NOTE: Because this setting is normally done automatically when 2-wire-type wired remote con-
troller is installed, setting is unnecessary.
Multiple indoor units can be operated by using one wired remote controller.
Set the unit number of each indoor unit.
Function number Setting value Setting description Factory setting
00
00 Unit no. 0
01 Unit no. 1
02 Unit no. 2
03 Unit no. 3
04 Unit no. 4
05 Unit no. 5
06 Unit no. 6
07 Unit no. 7
08 Unit no. 8
09 Unit no. 9
10 Unit no. 10
11 Unit no. 11
12 Unit no. 12
13 Unit no. 13
14 Unit no. 14
15 Unit no. 15
NOTE: When different type of indoor units (such as wall mounted type and cassette type, cassette
type and duct type, or other combinations) are connected using group control system, some
functions may no longer be available.
2) Filter sign
Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated
amount of dust in the air of the room.
If the indication is not required, select "No indication" (03).
Function number Setting value Setting description Factory setting
11
00 Standard (400 hours)
01 Long interval (1,000 hours)
02 Short interval (200 hours)
03 No indication
- 54 -
11-1. Function settings by using remote controller
11. Function settings
WALL MOUNTED
ASUG09-12LMAS
WALL MOUNTED
ASUG09-12LMAS