EasyManua.ls Logo

Fujitsu ASUH18LMAS - Additional Charge Calculation; Model: AOUH18 LMAS1; Model: AOUH24 LMAS1

Fujitsu ASUH18LMAS
96 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7. Additional charge calculation
7-1. Model: AOUH18LMAS1
Refrigerant type R410A
Factory charge amount
lb oz 3 lb 15 oz
g 1,800
¢ Refrigerant charge
Total pipe length
ft 49 or less 66 99 131 165 (Max.)
0.43 oz/ft
(40 g/m)
m 15 or less 20 30 40 50 (Max.)
Additional
charge
lb oz 0 7 oz 1 lb 5 oz 2 lb 3 oz 3 lb 1 oz
g 0 200 600 1,000 1,400
7-2. Model: AOUH24LMAS1
Refrigerant type R410A
Factory charge amount
lb oz 4 lb 10 oz
g 2,100
¢ Refrigerant charge
Total pipe length
ft 65 or less 99 131 165 (Max.)
0.43 oz/ft
(40 g/m)
m 20 or less 30 40 50 (Max.)
Additional charge
lb oz 0 14 oz 1 lb 12 oz 2 lb 10 oz
g 0 400 800 1,200
- 77 -
7-1. Model: AOUH18LMAS1
7. Additional charge calculation
OUTDOOR UNIT
AOUH18-24LMAS1
OUTDOOR UNIT
AOUH18-24LMAS1

Table of Contents

Other manuals for Fujitsu ASUH18LMAS

Related product manuals