Model: AUXG45KRLB
AFR
m
3
/h
1,870
Indoor temperature
°CDB 16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 12.04 4.31 11.75 4.33 11.46 4.35 11.19 4.35 10.53 4.35
-10 -11 13.37 4.49 13.05 4.52 12.73 4.54 12.43 4.54 11.69 4.54
-5 -7 14.70 4.68 14.35 4.70 14.00 4.72 13.67 4.72 12.86 4.72
0 -2 15.48 4.86 15.11 4.88 14.74 4.91 14.40 4.91 13.54 4.91
5 3 16.57 4.25 16.18 4.27 15.78 4.30 15.42 4.30 14.50 4.30
7 6 17.01 4.25 16.61 4.27 16.20 4.29 15.82 4.29 14.88 4.29
10 8 17.72 4.24 17.29 4.26 16.87 4.28 16.48 4.28 15.50 4.28
15 10 18.89 4.22 18.44 4.24 17.99 4.27 17.57 4.27 16.53 4.27
20 15 20.07 4.21 19.59 4.23 19.11 4.25 18.66 4.25 17.55 4.25
24 18 21.01 4.19 20.50 4.22 20.00 4.24 19.54 4.24 18.38 4.24
¢
Model: AUXG54KRLB
AFR
m
3
/h
2,100
Indoor temperature
°CDB 16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 12.26 4.49 11.97 4.51 11.67 4.53 11.40 4.53 10.72 4.53
-10 -11 13.62 4.68 13.29 4.70 12.97 4.72 12.66 4.72 11.91 4.72
-5 -7 14.97 4.87 14.61 4.89 14.26 4.92 13.93 4.92 13.10 4.92
0 -2 15.77 5.06 15.39 5.08 15.02 5.11 14.67 5.11 13.79 5.11
5 3 16.88 4.61 16.48 4.63 16.08 4.66 15.70 4.66 14.77 4.66
7 6 17.33 4.60 16.91 4.63 16.50 4.65 16.12 4.65 15.16 4.65
10 8 18.05 4.59 17.61 4.62 17.18 4.64 16.78 4.64 15.79 4.64
15 10 19.24 4.58 18.78 4.60 18.32 4.62 17.90 4.62 16.83 4.62
20 15 20.44 4.56 19.95 4.58 19.46 4.61 19.01 4.61 17.88 4.61
24 18 21.40 4.55 20.88 4.57 20.37 4.59 19.90 4.59 18.72 4.59
- 13 -
4-2. Heating capacity
4. Capacity table
CASSETTE TYPE
AUXG24-54KRLB
CASSETTE TYPE
AUXG24-54KRLB