Status Description
(orange)
The ETERNUS AF is under maintenance.
(yellow)
The ETERNUS AF is in warning state.
For details, refer to "Configuration Guide (Web GUI)".
Displaying Status via ETERNUS CLI
The status of the ETERNUS AF and the usage status of RAID groups, TPPs, and SDPs can be checked by sending
the status display command via ETERNUS CLI.
CLI> show status
Summary Status [Normal]
CLI> show status
Summary Status [Error]
CLI> show status
Summary Status [Warning]
The general status of the ETERNUS AF indicates whether an error status component or a warning status compo-
nent exists in the storage system.
Table 12 General Status of ETERNUS CLI
Status Description
Empty An undefined or uninstalled component exists in the ETERNUS AF.
Normal The ETERNUS AF is in a normal state.
Pinned Data Pinned data exists in the ETERNUS AF.
Unused An undefined component is installed in the ETERNUS AF.
Warning The ETERNUS AF contains a component that requires preventive maintenance.
Maintenance The ETERNUS AF is under maintenance.
Error An error has occurred in a component that is installed in the ETERNUS AF.
Loop Down The ETERNUS AF is in the BackEnd Down state.
Not Ready An abnormality is detected and access from the host cannot be received.
Subsystem Down The ETERNUS AF cannot be used.
Change Assigned CM CM hot expansion recovery is required.
Event Notification
By setting event notification, if an error (event) occurs in the ETERNUS AF, the event information is notified.
The methods that can be used to notify an event are "e-mail", "SNMP Trap", "Syslog", "remote support", and "host
sense".
For the procedure on setting event notification, refer to "Configuration Guide (Basic)".
3. Storage System Monitoring
Displaying Status via ETERNUS CLI
42
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays
Operation Guide (Basic)
Copyright 2019 FUJITSU LIMITED
P3AG-1842-06ENZ0