Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED P3AM-4842-12ENZ0
146
I 01020020 9 – –
%d
hot spare(s) released These messages are
notified when
"Added/Released
Hot Spare" is
enabled for
Informational Level
in the event
notification setting.
Enclosure=
&a
Slot=
&b
Type=
&c
RAID_Group_No=
&d
RAID_Group_Name=
&e
%d
hot spares are deleted.
%d
: Quantity
&a
: DE-ID ("00" for a controller enclosure)
&b
: Slot number
&c: Type (Global or Dedicated)
&d
: RAID group number (only for Dedicated
Hot Spares)
&e
: RAID group name (only for Dedicated
Hot Spares)
I 01030010 9 – –
%d
volume(s) created These messages are
notified when
"Operated Volume"
is enabled for
Informational Level
in the event
notification setting.
• For Standard volumes, SDVs, or SDPVs
No=
&a
Name=
&b
Type=
&c
Capacity=
&d
RAID_Group_No=
&e
RAID_Group_Name=
&f
• For TPVs
No=
&a
Name=
&b
Type=
&c
Capacity=
&d
Pool_No=
&g
Pool_Name=
&h
%d
volumes are created.
%d
: Quantity
&a
: Volume number
&b
: Volume name
&c: Volume type
&d
: Capacity
&e
: RAID group number (only for Standard/
Open volume, SDV, or SDPV)
&f
: RAID group name (only for Standard/
Open volume, SDV, or SDPV)
&g
: TPP number (only for Standard/Open
volume or TPV)
&h
: TPP name (only for Standard/Open
volume or TPV)
I 01030020 9 – –
%d
volume(s) deleted
No=&a Name=
&b
%d
volumes are deleted.
This message is not notified when the deletion
reservation function is used to delete the SDPV.
%d
: Quantity
&a
: Volume number
&b
: Volume name
I 01050010 9 – – Power on completed (
$a
)These messages are
notified when
"Power off/on Apply
Firmware" is
enabled for
Informational Level
in the event
notification setting.
Detail information is not displayed.
The device status is changed to Ready.
$a
: V
xx
L
xx
-
xxxx
(Firmware version)
I 01050020 9 – – Shutdown started
Detail information is not displayed.
Device shutdown has started.
I 01050030 9 – – Controller firmware updated (
$a
)
Detail information is not displayed.
Controller firmware version is updated.
$a
: V
xx
L
xx
-
xxxx
(Firmware version)
Event type
code
SNMP Trap
Upper: Message
Remarks
Middle: Detail information
Trap
No.
TrapItemId
TrapLink
StatusInfo
Lower: Description

Table of Contents