Appendix A Event Notification Message List
A.2 Message List
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Operation-
Copyright 2013 FUJITSU LIMITED P3AM-4842-12ENZ0
148
When the event type is "R"
The following messages are sent when a normal state is restored for Error or Warning level events.
Meaning of symbols
Message list
*1: This row indicates TrapWarningInfo for Trap No. 25 and TrapSensorInfo for Trap No. 26.
Symbol Meaning
SS Component subtype
MM CM module ID (10 – 11)
m CM number (0 – 1)
zz Model name (DX80S2 or DX90S2)
pp... Component number
ss... Serial number
rr... Version
eEXP number (0)
i IOM number (0 – 1)
d PSU number (0 – 1)
uu DE-ID ("00" for a controller enclosure)
Event type
code
SNMP Trap Upper: Message
Remarks
Trap
No.
TrapItemID (*1) Lower: Description
R 01
SSMM
00 25 0100
MM
00 0 Controller Module#
m
(
zz
) Normal <
pppppppppppp
ssssssssss
r
rrrr
>
These messages are
notified when "Recov-
ery module" is
enabled for Informa-
tional Level in the
event notification
setting.
Normal status is restored for a CM error.
R 06
SSMM
0
v
25 0600
MM
0
v
0 Controller Module#
m
(
zz
) EXP#
e
Normal
<
pppppppppppp
ssssssssss
r
rrrr
>
Normal status is restored for a CM EXP error.
R 90
SSuu
0
n
25 9000
uu
0
n
0IOM6 DE#
uu
/IOM#
i
Normal <
pppppppppppp
ssssssssss
r
rrrr
>
Normal status is restored for a DE IOM error.
R D2
SSuu
0
n
22 D200
uu
0
n
- Power Supply Unit DE#
uu
/PSU#
d
Normal
<
pppppppppppp
ssssssssss
rrrrr
>
Normal status is restored for a PSU error.
R DA
SSuu
00 26 DA00
uu
00 0 DE Exhaust temperature DE#
uu
Normal These messages are
notified when "Tem-
perature restoration"
is enabled for Infor-
mational Level in the
event notification
setting.
Normal status is restored for an exhaust temperature
error in CE or DE.
R DB
SSuu
00 26 DB00
uu
00 0 DE Intake temperature DE#
uu
Normal
Normal status is restored for an intake temperature
error in CE or DE.