EasyManua.ls Logo

Fujitsu Eternus DX80 S2 - Page 131

Fujitsu Eternus DX80 S2
147 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 5 Setup
5.2 ETERNUS DX Disk Storage System Monitoring Setup
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Installation-
Copyright 2013 FUJITSU LIMITED P3AM-4832-07ENZ0
131
â–  SNMP Trap test
Perform the SNMP Trap test to check that the SNMP Trap can be sent from the ETERNUS DX Disk storage
system to the SNMP Manager.
The SNMP Trap test setting is explained below.
Procedure
1 Perform the test transmission of the SNMP Trap.
1-1 Start ETERNUS Web GUI.
1-2 On the navigation of the ETERNUS Web GUI screen, click [System].
The [System] screen appears.
1-3 In [Category], click [Network].
The [Basic] tab screen of the [Network] screen appears.
1-4 In [Action], click [Send SNMP Trap].
The [Perform SNMP Trap Test] screen appears.
1-5 In the [Perform SNMP Trap Test] screen, click the [Send] button.
A confirmation screen appears.
1-6 Click the [OK] button.
The test transmission of the SNMP Trap is performed.
1-7 Check the transmission completion message and click the [Done] button.
The screen display returns to the [Network] screen.

Table of Contents

Other manuals for Fujitsu Eternus DX80 S2

Related product manuals