Chapter 5 Setup
5.3 Power Control Setup
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Installation-
Copyright 2013 FUJITSU LIMITED P3AM-4832-07ENZ0
140
5.3 Power Control Setup
Perform power control settings as required.
Power control setting is required when enabling the Auto Power function (AC automatic linkage mode) or the
Power Resume function (automatic power recovery mode), or when using the power control with the power
synchronized unit.
For details on the power control setup, refer to "ETERNUS Web GUI User’s Guide".
5.3.1 Setup of the Auto Power Function and/or the Power Resume Function
To automatically turn on the ETERNUS DX Disk storage system when AC power is supplied or when power is
restored after a power failure, use ETERNUS Web GUI to enable the Auto Power function and/or the Power
Resume function.
• Auto Power function (AC automatic linkage mode)
When the Auto Power function is enabled, the ETERNUS DX Disk storage system is automatically turned on
when AC power is supplied.
The Auto Power function is disabled for the factory default setting.
• Power Resume function (automatic power recovery mode)
When the Power Resume function is enabled, the ETERNUS DX Disk storage system is automatically turned
on when the power supply is restored after a power failure.
The Power Resume function is disabled for the factory default setting.
Table 5.1
shows how the ETERNUS DX Disk storage system operates when the Auto Power function and the
Power Resume function are enabled or disabled.
Table 5.1 ETERNUS DX Disk storage system operation according to the settings of the Auto Power function
and the Power Resume function
This section explains the procedure for the ETERNUS DX Disk storage system power control setup using
ETERNUS Web GUI. For the ETERNUS DX Disk storage system power control setup using ETERNUS CLI, refer to
"ETERNUS CLI User's Guide".
ETERNUS Web GUI settings How the ETERNUS DX Disk storage system operates
Auto Power function is disabled
Power Resume function is disabled
The ETERNUS DX Disk storage system is not automatically turned on even when
AC power is supplied or when power is restored after a power failure.
Auto Power function is enabled
Power Resume function is disabled
The ETERNUS DX Disk storage system is automatically turned on when AC power
is supplied.
The ETERNUS DX Disk storage system is not turned on even when power is
restored after a power failure.
Auto Power function is disabled
Power Resume function is enabled
The ETERNUS DX Disk storage system is not turned on even when AC power is
supplied.
The ETERNUS DX Disk storage system is automatically turned on when power is
restored after a power failure.
Auto Power function is enabled
Power Resume function is enabled
The ETERNUS DX Disk storage system is automatically turned on when AC power
is supplied and when power is restored after a power failure.