Chapter 2 Components
2.3 Power Distribution Units (For Regions other than EMEA&I)
ETERNUS DX80 S2/DX90 S2 Disk storage system User’s Guide -Installation-
Copyright 2013 FUJITSU LIMITED P3AM-4832-07ENZ0
44
2.3 Power Distribution Units (For Regions other than EMEA&I)
There are two sizes for power distribution units: 1U and 2U.
2.3.1 Power Distribution Units (1U)
The 1U power distribution unit has four outlets and two inlets.
Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 1U Max 2 enclosures connection)
Figure 2.28 Power distribution unit for DX80 S2/DX90 S2 (AC200-240V, 1U Max 2 enclosures connection)
Part explanation
Outlet (OUTPUT)
This is a socket (IEC60320-C13) for outgoing power supply. This socket is used to connect a power cord (AC
output cable).
Inlet (INPUT)
This is a socket (IEC60320-C14) for incoming power supply. This socket is used to connect a power cord (AC
input cable).
Main line switch
This turns on and off the power distribution unit.
Inlets (INPUT)
Outlets (OUTPUT)
Main line switches