Chapter 5 Information Settings and Display
5.1 Performance > start performance
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED P2X0-1030-09ENZ0
606
start performance
This command starts the collection of performance information. If performance information is already being
collected, then the command terminates with an error message.
Syntax
Parameter
Example(s)
start performance [ -interval { 30 | 60 | 90 | 120 | 150 | 180 | 210 | 240 | 270 | 300 } ]
-interval Optional. This parameter specifies the update interval for performance information. A unit is
second. If omitted, the default value (30 seconds) is used.
30 Updated every 30 seconds (default).
60 Updated every 60 seconds.
90 Updated every 90 seconds.
120 Updated every 120 seconds.
150 Updated every 150 seconds.
180 Updated every 180 seconds.
210 Updated every 210 seconds.
240 Updated every 240 seconds.
270 Updated every 270 seconds.
300 Updated every 300 seconds.
The following example starts collecting the performance information at 30 seconds intervals:
CLI> start performance -interval 30