Chapter 2 Status Display
2.1 Storage System Status > show fru-de
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED P2X0-1030-09ENZ0
62
show fru-de
This command displays the status of the components (Field Replaceable Units) in the drive enclosures.
Syntax
Parameter
Output
show fru-de [-de
enclosure_number
] [-type {iom0|iom1|psu0|psu1}]
-de Optional. This parameter specifies the drive enclosure number. Only one parameter can be
specified. If this parameter is omitted, all of the connected drive enclosures are displayed.
Example: -de 1
(Only the drive enclosure #1)
-type Optional. This parameter specifies the target component (FRU) name. The sub components
embedded in a drive enclosure will also be displayed. Only one parameter can be specified. If
this parameter is omitted, all of the FRUs are displayed.
iom0 Details and status of the I/O module #0
iom1 Details and status of the I/O module #1
psu0 Details and status of the Power Supply Unit #0
psu1 Details and status of the Power Supply Unit #1
The following table shows the output information for the IOM.
DE#n IOM#m Information (n: The drive enclosure number, m: The IOM number)
Status/Status Code
IOM#n status and the status code
Error Code Error code to identify error events that have occurred in an expander.
This information is only displayed when the Status is not "Normal" or "Undefined".
WWN World Wide Name
Active EC An EC number of the active firmware (The current operating firmware)
Next EC An EC number of the stand-by firmware (The generation number of the firmware after the
next power cycle)